beautypg.com

H2.pb - troubleshooting, H2 - technical data, Troubleshooting technical data – Siemens Gigaset 75 User Manual

Page 73: Troubleshooting, Technical data, About your system

background image

69

About your system

Gigaset 3070/3075isdn, GB, A31008-G3070-B100-3-7619

giga3070KAP.fm

09.01.01

Step

by

Step

Troubleshooting

Making calls:

Handset "dead"?

Charge the batteries (➔ see handset operating instructions).

Message: "Network section busy"?

Public network is overloaded. Try again later.

Message: "External lines seized"?

Both ISDN lines are already in use. Activate line reservation, see -> page 55.

Message: "No Trunk Access"?

Set "Unrestricted" access for handset, see "Accesses" on page 52.

Accepting calls:

Handset removed from charging unit but not connected?

Press

D

. You may have to activate Auto talk (see handset operating instruc-

tions).

Technical data

/

-
/

-
/

-
/

-

/

-

Transmit power

Medium range

10 mW

Top performance

250 mW

Range

Outdoors

approx. 300 m

Indoors

approx. 50 m

Power supply

Plug-in power supply
unit

220V/230 V ~/50 Hz

ISDN line

Euro ISDN multiple device connection IAE

Approved ambient condi-
tions for operation

Temperature

+5 °C to +45 °C

Rel. humidity

20% to 75%

This manual is related to the following products: