Ok Page 80
Page 80

70
997-01530-01, Rev. C-25, Jan 2008
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1
Where the value of each character in <123456789ABCDEFGHIJ> field is either 'E' or 'D'. 'E' means the
corresponding indicator is enabled, and can trigger an alarm if it enters a fault state. 'D' means the
indicator is disabled (or not available) and will not trigger an alarm if it enters a fault state.
To enable ('E'), disable (‘D’), or leave the indicator unchanged (‘-’), enter 'E', 'D', or '-' for each character
in <123456789ABCDEFGHIJ> when you enter the following string:
F73
The XL-GPS will sets the new alarm mask and responds:
OK
The following summarizes the fault alarm mask setting in the <123456789ABCDEFGHIJ> field:
Query or set Time Error Threshold using the THRESHOLD command. To query the Time Error
Threshold setting, enter:
F73
1
=
'E' PLL Synthesizer Alarm Enabled
'D' PLL Synthesizer Alarm Disabled
2
=
'D' not used
3
=
'E' GPS Alarm Enabled
'D' GPS Alarm Disabled
4
=
'D' not used
5
=
'D' not used
6
=
'D' not used
7
=
'D' not used
8
=
'D' not used
9
=
''D' not used
A
=
'E' DAC Alarm Enabled
'D' DAC Alarm Disabled
B
=
'E' First time lock Alarm Enabled
'D' First time lock Alarm Disabled
C
=
'E' Time error Alarm Enabled
'D' Time error Alarm Disabled
D
=
'E' Time out Alarm Enabled
'D' Time out Alarm Disabled
E
=
'E' NTP Alarm Enabled
'D' NTP Alarm Disabled (Default if NTP Option not enabled)