Code Out
The default output is IRIG-B-120 AM. Configuration is via the Keypad, Serial I/O, and Network port.
Five flags are encoded in the control function segment of the IRIG B code. The first flag encoded at
element P5+40ms is the LOCK indicator. It is a binary 1 when the reference source has become
unlocked. The second flag encoded at element P5+60ms is a binary 1 when the worst case time error
exceeds threshold 1 element P5+70ms is a binary 1 when the worst case time error exceeds threshold
2. Element P5+80ms encodes a binary 1 when the error exceeds threshold 3 and P5+90ms when the
error exceeds threshold 4.
The time code resets as follows:
Alarm
The open collector alarm output has the following states:
Format:
IRIG B-120 1 kHz AM -000 DC
Amplitude (AM):
3 Vp-p, into 50
Ω +/-10%
Ratio (AM):
3:1 +/-10%
Amplitude (DC):
TTL into 50
Ω
Qty:
1
Connector:
BNC female
Phasing:
In phase with carrier ± 10
μS
Accuracy:
Refer to
“Time and Frequency Accuracy” on page 3
Days Reset:
Resets to day 1 after day 365
Leap Year:
Resets to day 1 after day 366
Drive:
Open Collector
Max. Voltage:
25 VDC
Max. Current:
50 mA
Qty:
1
Connector:
BNC female
Off
(High Z) Power off
Off
(High Z) Error, major or minor enabled alarm fault.
On
(Low Z) Normal, no major or minor enabled alarm faults.