1

AC Power Supply

Input

Standard I/O

The following specifications apply to the connectors on the Main CPU card.

RS-232/RS-422 Interface

The standard serial data port is a bi-directional EIA standard RS 232C interface. The serial data port is
configurable via the Keypad and Network Port.

Factory settings for RS-232 9600,N,8,1

Input connector

IEC 320 type

Input voltage range

Universal, 90 - 260 VAC / 110-300 VDC

Input frequency range

47 Hz - 63 Hz

Interface:

RS-232, RS-422

Data Rates:

1200, 2400, 4800, 9600 and 19200 bps

Data Bits:

7 or 8

Parity:

even, odd or none for Data Bits 8, even or odd for Data Bits 7

Stop Bits:

1 or 2

Connector:

Male 9 pin D subminiature

Pin Assignment:

1------N/C

2------Rx (RS-232)

3------Tx (RS-232)

4------N/C

5------GND

6------Rx- (RS-422)

7------Rx+ (RS-422)

8------Tx- (RS-422)

9------Tx+ (RS-422)