beautypg.com

Sample request, Xl-gps responds (example), Xl-gps responds – Symmetricom XL-GPS User Manual

Page 105: F110

background image

997-01530-01, Rev. C-25, Jan 2008

95

2

5

1

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

Sample request:

F110

XL-GPS responds (example):

F110 TIET 50 POSITIVE

To the configure TIET input with a different impedance value, enter (example):

F110 TIET 100K POSITIVE

XL-GPS responds:

OK

To obtain TIET measurement from J1, enter:

F110 TIET TIME

XL-GPS responds:

OK

.xxxxxxxxx

(Time Interval (display continues until function termination with Ctrl+C)

Or, (example):

F110 TIET EVENT

XL-GPS responds:

OK

ddd:hh:mm:ss.xxxxxxxxx

(Event Timing display continues until function termination with Ctrl+C)

F110 responds "F110 TIET OPTION IS NOT ENABLED" to any of the commands above if the TIET
option has not been enabled by the operator using the F126 Options Key Entry command.

= 100K,

50

= line terminator, either a carriage return and line feed for output strings or a

carriage return only for input strings.

F

= ASCII character F.