SATO CT410 User Manual
Page 147

Counter Status (SOH + ME)
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ME
(hexadecimal 4D45) causes the printer to return a 28 byte Head Counter Status Word
bounded by an STX-ETX pair that reports the current status of the printer life
counters.
BYTE
NUMBER
VALUE
DESCRIPTION
1-8
Binary
Current Life Counter in dots
9-12
Binary
1st (Current) Head Counter in dots
13-16
Binary
2nd (Previous) Head Counter in dots
17-20
Binary
3rd Head Counter in dots
21-24
Binary
Cutrrent Cut Counter in dots
25-28
Binary
Current Dispense Counter in dots
Sensor Status (SOH + SG)
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an SG
(hexadecimal 5347)causes the printer to return a 4 byte Sensor Status Word bounded
by an STX-ETX pair that reports the values of the printer counters.
BYTE
NUMBER
VALUE
DESCRIPTION
1
Binary
See-Thru Sensor Level (0 to 255)
2
Binary
Transmissive Sensor Level (0 to 255)
3
00
H
01
H
Out of Paper
Paper Present
4
00
H
01
H
Head Open
Head Closed
Section 5. Interface Specifications
SATO CT Series Printers
90010
69A