Command Structure

BPn...n

n...n =

5 digits (Postnet-32 format)
6 digits (Postnet-37 format)
9 digits (Postnet-52 format)
11 digits (Postnet-62, Delivery Point format)

Example:

BP123456789

Placement:

Immediately preceding the data to be encoded

Default:

None

Command Function

To print Postnet bar codes

Printer Input

A
H0100V0120BP94089
H0100V0160BP123456
H0100V0200BP123456789
H0100V0240BP12345678901
Q1Z

Printer Output

Special Notes

1. If the number of data digits does not match those listed, the

command is ignored.