Siemens Simotion A4027118-A0414 User Manual
Page 73
Section C: Integrating the core “flying saw” functions
Integrating the core “flying saw” functions
Flying Saw with SIMOTION
A4027118-A0414
V 1.4
Release 06/06/08
73/107
C
opyr
ight
©
Si
em
ens
AG 2
0
08
Al
l r
ights r
e
s
e
rv
ed
M
anual_
S
IM
OTION Fl
ying Saw
_
V1
.4.
d
oc
Table 7-2 Software components
Software
Diagram
Order No./MLFB and functions
Version used
STEP 7
6ES7810-4CC07-0YA5
Step7 is the basis package for all
optional software packages and is used
to program the SIMATIC S7.
V5.3 SP3 HF1
SIMOTION
SCOUT
6AU1810-0BA40-0XA0
SCOUT is the engineering tool to
program all SIMOTION controls
V4.0.0
This form of the installation has been used when generating the standard
“flying saw” application and should therefore be the preferred one for users.
7.2.2 SIMOTION
control
A SIMOTION control is required to operate the core “flying saw” functions.
All SIMOTION D, SIMOTION P and SIMOTION C controls can be used.
.
Note
The application example has been developed and tested for use in
conjunction with the SIMOTION D training case with CPU D435.
Modifications and changes may have to be made when used in another
hardware environment
.
In order to correctly use the program elements in this document, you should
be knowledgeable about handling, and programming the control being used
as well as its functions.
Table 7-3 Hardware components of the core “flying saw” functions
Hardware element
Diagram
Order No./MLFB and functions
SIMOTION CPU
D435
6AU1435-0AA00-0AA0 Version C
The CPU D435 processes the user
program, the technology and checks the
drives.
SIMOTION
D435
32MB CF-Card
6AU1400-2JA00-0AA0
The SIMOTION program and the
SINAMICS configuring are saved on the
CF card.