beautypg.com

Standard operator control – Siemens Simotion A4027118-A0414 User Manual

Page 55

background image

Section B: The application example as demonstration

system

O

t

t l f th

li

ti

l

Flying Saw with SIMOTION

A4027118-A0414

V 1.4

Release 06/06/08

55/107

C

opyr

ight

©

Si

em

ens

AG 2

0

08

Al

l r

ights r

e

s

e

rv

ed

M

anual_

S

IM

OTION Fl

ying Saw

_

V1

.4.

d

oc

Standard operator control

Table 5-3: Standard operator control in the automatic mode

No.

Action

Comment

1 Initial situation:

The “flying saw” is in the AUTOMATIC-STOPPED mode

2 Using the Sync Position slider switch, enter the position

at which the flying saw reaches the position where the
material web is to be cut.

3 The flying saw starts to move to the starting position by

pressing the Flying Saw STARTPOS button

4 After the starting position has been reached, the flying

saw is in the AUTOMATIC-READY mode

5 The flying saw is enabled for operation using the Flying

Saw START button.

6 The flying saw is in the AUTOMATIC-STANDBY mode

and waits for material.

7 Select the required material web velocity using the

Material Velocity slider.