Section B: The application example as demonstration
system
I
t lli
th h d
d
ft
Flying Saw with SIMOTION
A4027118-A0414
V 1.4
Release 06/06/08
33/107
C
opyr
ight
©
Si
em
ens
AG 2
0
08
Al
l r
ights r
e
s
e
rv
ed
M
anual_
S
IM
OTION Fl
ying Saw
_
V1
.4.
d
oc
6 Open Properties by double-clicking on
the PG/PC(1).
7 Under the “Assignment” tab (this is
already automatically selected), the
ETHERNET interface used must be listed
under “Assigned”. If this is already the
case, then select this and set the
checkmark for S7ONLINE access active.
In this case, you skip steps 8 and 9!
Acknowledge your entry with OK.
Under certain
circumstances, the
Ethernet line of the
PG/PC will have a
”yellow border”.
If the ETHERNET interface used is still
not listed under “Assigned” then
execute steps 8 and 9 (but only then!).
8 The ETHERNET interface is still not
“assigned”:
The configured interface of the control is
listed under “Configured Interfaces” and
all of the available interfaces of the
PG/PC are under “Interface Parameter
Assignments in the PG/PC”.
Select the ETHERNET interface to be
used under “Interface Parameter
Assignments in the PG/PC” (just the
same as set in “Set PG/PC interface”)
and press the Assign button.
If a warning is displayed, then
acknowledge this with OK.