6program environment and interfaces – Siemens Simotion A4027118-A0414 User Manual
Page 62
Section C: Integrating the core “flying saw” functions
Program environment and interfaces
Flying Saw with SIMOTION
A4027118-A0414
V 1.4
Release 06/06/08
62/107
C
opyr
ight
©
Si
em
ens
AG 2
0
08
Al
l r
ights r
e
s
e
rv
ed
M
anual_
S
IM
OTION Fl
ying Saw
_
V1
.4.
d
oc
6
Program environment and interfaces
6.1.1
Function and identification of the program groups
The standard “flying saw” application is sub-divided into the following
program groups:
• OMAC
• SAP
• FS
• SIM
• HMI
OMAC
In the OMAC program group, the operating mode manager is used
according to the OMAC standard of the standard SIMOTION Easy Basics
(SEB) application.
SAP
Program group to solve automation tasks (demo) machine with the
application example of the standard “flying saw” application. Based on the
SIMOTION D demonstration case, the mode of operation and core
functions of the standard application are presented/demonstrated in
conjunction with a WinCCflex-base visualization system.
FS
Program group with the core functions of the standard “flying saw”
application.
This program group includes the "flying saw" TEMPLATE and
supplementary functions to manage the synchronous position.
SIM
Program group to simulate system signals in the demonstration case
environment
HMI
Program group to display system sequences on the WinCCflex operator
interface (screen)