Juniper Networks E-Series User Manual
Page 138

CHAPTER 11
System Specifications
11-2
Airflow
•
An integral air plenum directs router’s exhaust air below the router and out
the back. See
Chapter 3, Installation Guidelines and
DC Input
Voltage
Current
Power
Redundancy (input power)
–40 to –72 VDC
a
50 A @ –48 VDC
2400 W maximum
2 independent line feeds
NEBS Certification
•
SR-3580 (FD-15): Network Equipment Building System (NEBS) Criteria
Levels, Issue 1, November 1995
•
GR-63 (LSSGR, FD-15): Network Equipment Building System (NEBS)
Requirements: Physical Protection, Issue 1, October 1995
•
GR-1089 (LSSGR, FD-15): Electromagnetic Compatibility and Electrical
Safety - Generic Criteria for Network Telecommunications Equipment, Issue
2, Revision 1, February 1999
Safety Agency Certification
•
AS/NZS 3260:1993, Safety of Information Technology Equipment Including
Electrical Business Equipment
•
CAN/CSA C22.2, No. 60950-00, 3rd Edition, Safety of Information
Technology Equipment
•
EN60825-1, Safety of Laser Products - Part 1: Equipment Class,
Requirements, and User’s Guide (2001)
•
EN60950:2000, 3rd Edition, Safety of Information Technology Equipment
•
IEC 60950-1(2001-10) Ed. 1.0 Information technology equipment - Safety -
Part 1: General requirements
•
Low Voltage Directive (73/23/EEC)
•
UL 60950, 3rd Edition, Safety of Information Technology Equipment
Electromagnetic Emissions
Agency Certification
•
AS/NZS 3548:1995 (CISPR 22 Class A)
•
EMC Directive (89/336/EEC)
•
EN55022 Class A (CISPR-22 Class A)
•
EN55024, Annex C for WAN Equipment Performance Criteria A, B, and C
•
ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic
Compatibility (EMC) requirements
•
FCC Part 15 Class A
•
IECS-003 Issue 3 Class A
•
VCCI (Voluntary Control Council for Interference by Information Technology
Equipment)
Table 11-1 ERX-14xx models specifications (continued)
Category
Specification