beautypg.com

Motion detection with freely determined, Sensitivity levels – JVC VR-509E User Manual

Page 36

background image

Recording Camera Images

36

When the [M. DET] value on the [REC PATTERN SET] screen

is set at “USER”, it is possible to set the sensitivity for

[DYNAMIC SENSITIVITY LEVEL], [TARGET AREA LEVEL]

and [STOP LEVEL]. These settings have no effect if anything

other than [USER] has been specified.

1. Press the [MENU] button.

• The [MENU]

→ [RECORD SETUP] → [ALARM REC]

screens will be displayed in this sequence in accordance

with the [MENU Screen Operations] explained on

page 17.

2. Select the camera input that is to be set up with [

W/X]

keys.

3. Select your desired item with the [

S/T] keys, and then

change the value of the setting with [–/+].

Settings

The level value for detection. The higher the value, the higher

the sensitivity.

Setting Range:

1 (low sensitivity) to 10 (high sensitivity)

The offset value for the stop level of operation sensitivity. The

larger the value, the more difficult to discontinue alarm

detection.

Setting Range:

1 to 3

The level value for the size of the subject to be detected. The

higher the value, the more difficult it is to detect small motions.

Setting Range:

1 (small) to 10 (large)

4. Press the [SET] button.

• The confirmation screen will be displayed.

5. Select [SAVE] with the [

W/X] keys, and then press

[SET] button.

Use the manual settings if the desired level of detection is not

attained with STANDARD or other scenes. These three

parameters should be determined after referring to [Table #1:

Motion Detect Parameters for Each Scene] and [Table #2:

Target Area Level and Detection Area Count] on page 35.

Motion Detection with Freely Determined
Sensitivity Levels

DYNAMIC SENSITIVITY LEVEL

STOP LEVEL

TARGET AREA LEVEL

ALARM REC

3.

2.

CAMERA INPUT

DURATION
PREALARM REC
MOTION DETECT SET
DYNAMIC SENSITIVITY LEVEL (DEFAULT:8)
STOP LEVEL

(DEFAULT:2)
(DEFAULT:2)

TARGET AREA LEVEL
MOTION DETECT AREA SET ..

CAMERA 1

3 MIN

10SEC

8
2
2

About Manual Setup