Setting the alarm recording, Ending the alarm recording – JVC VR-509E User Manual
Page 34
Recording Camera Images
34
1. Press the [MENU] button.
• The [MENU]
→ [RECORD SETUP] → [ALARM REC]
screens will be displayed in this sequence in accordance
with the [MENU Screen Operations] explained on
2. Select the camera input that is to be set up with [
W/X].
3. Select your desired item with the [
S/T] keys, and then
change the value of the setting with [–/+].
Settings
10 SEC, 15 SEC, 30 SEC, 1 MIN, 3 MIN, 5 MIN:
Alarm recording is performed only for the period of
time set.
When an additional alarm is detected during alarm
recording, the recording will be extended only for the
amount of time set from that point.
MANUAL: Recording is continued during the period a signal is
being input.
OFF: Pre-alarm recording is not performed.
10 SEC, 30 SEC, 60 SEC:
Pre-alarm recording is performed for the period of time
set.
4. Press the [SET] button.
• The confirmation screen will be displayed.
5. Select [SAVE] with the [
W/X] keys, and then press
[SET] button.
* Pre-alarm recording is only performed for alarm detection
when ALARM REC has been set and recording is not being
carried out at that time.
Details on pre-alarm recording are explained on page 105.
* Alarm recording (includes motion detection) will not be
carried out when the setup menu is open.
Alarm recording is stopped when [ALARM RESET] button is
pressed and when a signal is input to the [ALARM RESET]
terminal during alarm recording (alarm input terminal, motion
detection.)
* When alarm recording is cancelled, alarm recording triggered
by new motion detection signals will not be accepted for
fifteen seconds.
Press [ALARM RESET] button during alarm recording.
• Alarm recording will be stopped.
Input a signal to the [ALARM RESET] terminal during
alarm recording.
• Alarm recording will be stopped.
* Set the frame rate for [ALARM REC] at anything other than
“--” for [CAMERA SETUP-3] or [REC PATTERN SET] when
alarm recording is to be carried out.
* There are cases where the search time during playback will
require additional time if the number of alarms is increased.
Setting the ALARM Recording
DURATION
PREALARM REC
ALARM REC
3.
2.
CAMERA INPUT
DURATION
PREALARM REC
MOTION DETECT SET
DYNAMIC SENSITIVITY LEVEL (DEFAULT:8)
STOP LEVEL
(DEFAULT:2)
(DEFAULT:2)
TARGET AREA LEVEL
MOTION DETECT AREA SET ..
CAMERA 1
3 MIN
10SEC
8
2
2
Ending the ALARM Recording
Canceling the Alarm with the Button on the
Front Panel
Canceling the Alarm with the Signal Input
Terminal