Recording Camera Images

34

1. Press the [MENU] button.

• The [MENU]

→ [RECORD SETUP] → [ALARM REC]

screens will be displayed in this sequence in accordance

with the [MENU Screen Operations] explained on

page 17.

2. Select the camera input that is to be set up with [

W/X].

3. Select your desired item with the [

S/T] keys, and then

change the value of the setting with [–/+].

Settings

10 SEC, 15 SEC, 30 SEC, 1 MIN, 3 MIN, 5 MIN:

Alarm recording is performed only for the period of

time set.

When an additional alarm is detected during alarm

recording, the recording will be extended only for the

amount of time set from that point.

MANUAL: Recording is continued during the period a signal is

being input.

OFF: Pre-alarm recording is not performed.

10 SEC, 30 SEC, 60 SEC:

Pre-alarm recording is performed for the period of time

set.

4. Press the [SET] button.

• The confirmation screen will be displayed.

5. Select [SAVE] with the [

W/X] keys, and then press

[SET] button.

* Pre-alarm recording is only performed for alarm detection

when ALARM REC has been set and recording is not being

carried out at that time.

Details on pre-alarm recording are explained on page 105.

* Alarm recording (includes motion detection) will not be

carried out when the setup menu is open.

Alarm recording is stopped when [ALARM RESET] button is

pressed and when a signal is input to the [ALARM RESET]

terminal during alarm recording (alarm input terminal, motion

detection.)

* When alarm recording is cancelled, alarm recording triggered

by new motion detection signals will not be accepted for

fifteen seconds.

„ Press [ALARM RESET] button during alarm recording.

• Alarm recording will be stopped.

„ Input a signal to the [ALARM RESET] terminal during

alarm recording.

• Alarm recording will be stopped.

* Set the frame rate for [ALARM REC] at anything other than

“--” for [CAMERA SETUP-3] or [REC PATTERN SET] when

alarm recording is to be carried out.

(Page 21, 31)

* There are cases where the search time during playback will

require additional time if the number of alarms is increased.

Setting the ALARM Recording

DURATION

PREALARM REC

ALARM REC

3.

2.

CAMERA INPUT

DURATION
PREALARM REC
MOTION DETECT SET
DYNAMIC SENSITIVITY LEVEL (DEFAULT:8)
STOP LEVEL

(DEFAULT:2)
(DEFAULT:2)

TARGET AREA LEVEL
MOTION DETECT AREA SET ..

CAMERA 1

3 MIN

10SEC

8
2
2

Ending the ALARM Recording

Canceling the Alarm with the Button on the

Front Panel

Canceling the Alarm with the Signal Input

Terminal