beautypg.com

Alarm recording, Setting the alarm terminal – JVC VR-509E User Manual

Page 33

background image

33

Recording Camera Images

Alarm recording is started when alarm signals are input and
when motion is detected in the STOP mode and during normal
recording and timer recording.

1. Connect the [EMERGENCY] terminal to the alarm device.

2. Setting the [RECORD SETUP] screen. (Page 30)

Set the [EMERGENCY REC DURATION] setting to
anything other than “OFF”.

3. Setting for the alarm terminal. (Page 33)

Select the camera that is to be used for emergency
recording with the [EMERGENCY REC] setting.

4. Setting for the alarm recording. (Page 34)

Set the emergency recording time with the [DURATION]
setting.

„ Recording is started when a signal is input to the

[EMERGENCY] terminal.

1. Connect the [ALARM IN] terminal to the alarm device.

2. Setting the [RECORD SETUP] screen. (Page 30)

Set whether audio recording is to be activated or not with
the [ALARM AUDIO REC] setting.

3. Setting the [REC PATTERN SET] screen. (Page 31)

Set the [F.RATE (ips)] setting for [ALARM REC] to anything
other than “---”.

4. Setting for the alarm terminal (Page 33)

Select the camera that is to be activated for the alarm input
terminal.

5. Setting for the alarm recording (Page 34)

Set whether the alarm recording time and pre-alarm
recording time are to be activated or not.

„ Recording is started when a signal is input to the [ALARM

IN] terminal.

1. Setting the [RECORD SETUP] screen. (Page 30)

Set whether alarm audio recording is to be activated or not
with the [ALARM AUDIO REC] setting.

2. Setting the [REC PATTERN SET] screen. (Page 31)

• Set the [F.RATE (ips)] setting for [ALARM REC] to

anything other than “---”.

• Set the [M.DET] setting to anything other than “OFF”.

3. Setting for the alarm recording. (Page 34)

• Set whether the alarm recording time and pre-alarm

recording time are to be activated or not.

• Set the motion detection level. (Only when “USER” has

been specified for [M.DET] on the [REC PATTERN SET]
screen.)

4. Setting for the motion detection area. (Page 37)

„ Recording is started when motions is detected in the input

image.

1. Press the [MENU] button.

• The [MENU]

→ [RECORD SETUP] → [ALARM

TERMINAL] screens will be displayed in this sequence in
accordance with the [MENU Screen Operations]
explained on page 17.

• The screen will display a matrix that shows the alarm

input terminals on the vertical axis and the camera input
on the horizontal axis.

• If a camera input number is displayed on the right-hand

side of the port number when a signal is input to each of
the alarm input terminals it is enabled, and if “-” is
displayed it is disabled.

* The corresponding camera input can also be set up for

the emergency recording terminal in the same way.

2. Select your desired item with the [

S/T/W/X] keys, and

then change the value of the setting with [–/+].

Settings

(1), (2), (3), (4), (5), (6), (7), (8), (9):

Recording of selected camera is started when a signal
is input to the terminal.

(–):

Recording is not started even when signals are input to
the terminal.

3. Press the [SET] button.

• The confirmation screen will be displayed.

4. Select [SAVE] with the [

W/X] keys, and then press

[SET] button.

ALARM Recording

Emergency Recording

Alarm Recording (Alarm Input Terminal)

Alarm Recording (Motion Detection)

Setting the ALARM TERMINAL

ALARM PORT

Corresponding Camera

ALARM TERMINAL

2.

ALARM PORT
PORT1
PORT2
PORT3
PORT4
PORT5
PORT6
PORT7
PORT8
PORT9
EMERGENCY REC

(1)(–)(–)(–)(–)(–)(–)(–)(–)
(–)(2)(–)(–)(–)(–)(–)(–)(–)
(–)(–)(3)(–)(–)(–)(–)(–)(–)
(–)(–)(–)(4)(–)(–)(–)(–)(–)
(–)(–)(–)(–)(5)(–)(–)(–)(–)
(–)(–)(–)(–)(–)(6)(–)(–)(–)
(–)(–)(–)(–)(–)(–)(7)(–)(–)
(–)(–)(–)(–)(–)(–)(–)(8)(–)
(–)(–)(–)(–)(–)(–)(–)(–)(9)

(1)(2)(3)(4)(5)(6)(7)(8)(9)

The [ALARM] indicator on the front panel will be
illuminated during alarm recording and emergency
recording. This will then blink when recording has
finished.

A buzzer will sound during alarm and emergency
recording if the [ALARM] setting on the [BUZZER]
screen is set at “ON”. (See page 49)

Alarm recording will not be carried out when the setup
menu is being displayed.

The recording frame rate will be the total number of frames
divided equally into the value entered for emergency
recording when emergency recording (passcode error
recording) is in operation (Total frame count: 120 frames
when the PRIORITY mode is [SMOOTH] and 60 frames
when it is [HIGH-RESOLUTION] ).

MEMO