Installation and Preparation

20

1. Press the [MENU] button.

• Open the menus in accordance with the instructions

provided in MENU Screen Operations (page 17) in the

sequence of [MENU]

→ [CAMERA SETUP].

• The [CAMERA SETUP-1] screen will be displayed.

* The settings cannot be amended during recording.

2. Select “CONTINUE” on the confirmation screen with

the use of the [

W/X] keys, and then press the [SET]

button.

• The confirmation screen will close.

* Select “ABORT” and press the [SET] button to return to

the top menu.

3. Select your desired item with [

S/T], and then press

[–/+] to change the value settings.

Settings

CONNECT, DISCONNECT:

Set the camera input that is to be used for

recording at “CONNECT”, and all other cameras

at “DISCONNECT”.

SMOOTH:

Set and record with a total recorded frame count

of 100 images per second, and a picture size of

352 x 288 pixels.

HIGH-RESOLUTION:

Set and record with a total recorded frame count

of 50 images per second, and a picture size of

720 x 288 pixels.

4. Press the [SET] button.

• The [CAMERA SETUP-2] screen will be displayed.

5. Select your desired item with [

S/T], and then press

[–/+] to change the value settings.

Settings

1DAY, 3DAYS, 5DAYS, 1WEEK, 2WEEKS, 3WEEKS,

1MONTH, 2MONTH, 3MONTH:

Set the period for which the recorded images are to

be stored on the hard disk based on the preset

recorded image mode and the number of cameras

connected.

* This storage period only acts as a guidelines, as the actual

period of storing images may differ depending on

amendments to the frame rate, quality and other settings in

[CAMERA SETUP-3]. (Refer to the section on “Recording

Duration” on page 110 for further details on the storage

period for recorded images.)

ON, OFF: Set whether to record sound audio when in the

NORMAL REC and ALARM REC modes.

Set the action when the remaining capacity in the hard disk

becomes empty.

OFF:

Stops recording.

ALARM LOCK: Continues recording over old recordings.

However, recordings made in the ALARM REC

mode will not be overwritten.

ALL:

Continues recording over old recordings.

Installation Settings

CAMERA SETUP-1

CAMERA1 to 9

PRIORITY

CAMERA SETUP

RECORD SETUP

OPERATION MENU

LIVE PICTURE

Button operation explanation

FUNCTION : USER GUIDANCE

SET UP
CURSOR
UPDATE/NEXT

BACK

3.

Confirmation
screen

2.

CAMERA SETUP-1

CAM 1
CAM 2
CAM 3
CAM 4
CAM 5
CAM 6
CAM 7
CAM 8
CAM 9
PRIORITY

CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
CONNECT
SMOOTH

CONTINUE

ABORT

The current setting is changed when preserving it.

CAMERA SETUP-2

DURATION

AUDIO REC

REPEAT REC

When the setting has been made for a specific number of

cameras, it is only possible to amend [CAMERA SETUP-1].

In order to amend the subsequent cameras, the [REC

PATTERN SET] data (the F.RATE, QLY, and M.DET

settings for NORMAL REC/ALARM REC) that use

[STANDARD] or [REC PATTERN 1 to 9] must be reset.

(See “Setting the REC PATTERN SET” on page 31)

CAUTION

DURATION
AUDIO REC
REPEAT REC

CAMERA SETUP-2

1 WEEK

OFF
OFF

5.