VIS-CAM System


84

Appendix C: Two Cameras, One-Flash Configuration

Table 35

Master to slave connections.

Master Flash Connector (X5)

Slave Laser Connector (X7)

Pin 2

Pin 2

Pin 3

Pin 3

Pin 5

Pin 1

• Junction Panel trigger polarity switch in position “positive going edge”
• Master camera flash must be set to “auto” in Properties section of ENSetup software
• Slave camera flash must be set to “light sensor control” in properties section of ENSetup

software