JAI VIS-CAM System TS-1327EN User Manual
Page 103
![background image](/manuals/132013/103/background.png)
Appendix E: Moxa N Port 5232 Configuration
91
VIS-CAM System
Operating settings port 1:
Operation mode:
TCP – specify the operation mode of the serial channel – currently TCP is
required for communication with the TLS200 light sensor – UDP will be
implemented in the nearer future.
TCP alive check time:
1 - Specify the alive time for the TCP communication.
Inactivity time:
0 – Specify the timeframe for closing an idle serial line.
Max connections:
4 – Specify the amount of simultaneous TCP connections.
Ignore jammed IP
Yes
Allow driver control
No
Data Packing
Delimiter 1:
D – Specify the size of the delimiter (entry in Hex).
Force transmit:
30 – Specify the time frame for forced transmit (entry in mS).
TCP Server Mode
Local TCP port:
4001 – Specify the broadcast port. 4001 is default.
Command port:
966 – Specify the command port. 966 is default.
Figure 92. Operation configuration of Serial port 1: