Aes/ebu hookup with pdi, Cables & hardware, Hookup – MACKIE Digital 8Bus D8B v5.1 User Manual
Page 130: Hdr24/96 settings, Console settings
D8B Manual • Chapter 4 • page 124
AES/EBU Hookup to HDR24/96 (PDI•8)
Cables & Hardware
(3) PDI•8 cards for HDR24/96
(3) PDI•8 cards for D8B
(1) Clock I/O card for D8B
(3) DB25 to DB25 AES/EBU snakes
(1) 75
Ω BNC word clock cable
Hookup
1. Connect the three AES/EBU cables
between the corresponding AES/EBU
connectors on the HDR24/96 and D8B.
2. When AES/EBU is used, the D8B
must have a Clock I/O card installed.
To make the D8B the clock master,
connect its Word Clock Out to the
HDR24/96 Word Clock In. To make
the HDR24/96 the master, connect its
Word Clock Out to the D8B Word
Clock In.
HDR24/96 Settings
1. If the HDR24/96 is the clock master,
set the Sample Clock to Internal; if it
is a clock slave, set the Sample Clock
to Word Clock and depress the 75
Ω
termination switch on the Sync card.
2. Set the Sample Rate to 44.1kHz or
48kHz according to your preference.
Console Settings
1. If the D8B is the clock master, set the
Sample Rate
to either 44.1kHz or
48kHz
, and set the Apogee Clock to
Internal
(in the Digital I/O Setup
window). If it is a clock slave, then set
the Apogee Clock to Word Clock. Set
the Sample Rate to match the Sample
Rate
selected on the HDR24/96.
AES/EBU Hookup with PDI
•
8
PDI•8
AES/EBU I/O
AES/EBU
Cables
(DB25)
PDI•8 I/O Cards
Digital 8•Bus
HDR 24/96
APOGEE
SYNC
APOGEE
Word Clock Out
Word Clock
In
Word
Clock Out
(HDR24/96
as Master)
Word
Clock Out
(D8B as
Master)
Word
Clock In
Word
Clock
Out
Apogee
Clock I/O
Card
S
C
NOT
WARNING
HDR
Sync
Card
Word
Clock In
Word
Clock
Out
Use
one
only
Depress the
Termination
button if the
HDR24/96 is
set to Slave
PDI•8
AES/EBU I/O
PDI•8
AES/EBU I/O
PDI•8
AES/EBU I/O
PDI•8
AES/EBU I/O
PDI•8
AES/EBU I/O
PDI•8
I/O Cards