Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- A User Manual
Page 95
![background image](/manuals/118458/95/background.png)
3 - 48
3. SIGNALS AND WIRING
(2) For 1-phase 100 to 120VAC or 1-phase 230VAC power supply
RA
OFF
ON
MC
MC
SK
NFB
MC
L
1
L
2
L
3
L
11
L
21
EMG
SON
SG
VDD
COM
ALM
RA
Power supply
1-phase 100 to
120VAC or
1-phase 230VAC
Emergency stop
Servo-on
(Note 2)
Servo amplifier
Trouble
Emergency
stop
(Note 1)
Note 1. Configure the power supply circuit to shut off the magnetic contactor after detecting an alarm occurrence on the
controller side.
2. Not provided for 1-phase 100 to 120VAC.