Troubleshooting – MITSUBISHI ELECTRIC MR-J2S- A User Manual
Page 205
10 - 8
10. TROUBLESHOOTING
Display
Name
Definition
Cause
Action
1. Faulty parts in the servo amplifier
Checking method
Alarm (AL.15) occurs if power is
switched on after disconnection
of all cables but the control
circuit power supply cables.
AL.15
Memory error 2 EEP-ROM fault
2. The number of write times to EEP-
ROM exceeded 100,000.
Change the servo amplifier.
1. Encoder connector (CN2)
disconnected.
Connect correctly.
2. Encoder fault
Change the servo motor.
AL.16
Encoder error 1 Communication
error occurred
between encoder
and servo amplifier. 3. Encoder cable faulty
(Wire breakage or shorted)
Repair or change the cable.
CPU/parts fault
1. Faulty parts in the servo amplifier.
Checking method
Alarm (AL.17) occurs if power is
switched on after disconnection
of all cable but the control circuit
power supply cable.
Change the servo amplifier.
AL.17
Board error
The output
terminals U, V, W of
the servo amplifier
and the input
terminals U, V, W of
the servo motor are
not connected.
2. The wiring of U, V, W is
disconnected or not connected.
Correctly connect the output terminals U,
V, W of the servo amplifier and the input
terminals U, V, W of the servo motor.
AL.19
Memory error 3 ROM memory fault Faulty parts in the servo amplifier.
Checking method
Alarm (AL.19) occurs if power is
switched on after disconnection
of all cable but the control circuit
power supply cable.
Change the servo amplifier.
AL.1A
Motor
combination
error
Wrong combination
of servo amplifier
and servo motor.
Wrong combination of servo amplifier
and servo motor connected.
Use correct combination.
1. Encoder connector (CN2)
disconnected.
Connect correctly.
Communication
error occurred
between encoder
and servo amplifier.
2. Encoder cable faulty
(Wire breakage or shorted)
Repair or change the cable.
3. Encoder fault
Change the servo motor.
AL.20
Encoder error 2
Encoder detected
acceleration error.
4. Excessive acceleration is occurred
due to oscillation and others.
1. Decrease the speed control gain 2.
2. Decrease the auto tuning response
level.
1. Power input wires and servo motor
output wires are in contact at
main circuit terminal block (TE1).
Connect correctly.
2. Sheathes of servo motor power
cables deteriorated, resulting in
ground fault.
Change the cable.
AL.24
Main circuit
error
Ground fault
occurred at the
servo motor outputs
(U,V and W phases)
of the servo
amplifier.
3. Main circuit of servo amplifier
failed.
Checking method
AL.24 occurs if the servo is
switched on after disconnecting
the U, V, W power cables from
the servo amplifier.
Change the servo amplifier.