beautypg.com

Troubleshooting – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 205

background image

10 - 8

10. TROUBLESHOOTING

Display

Name

Definition

Cause

Action

1. Faulty parts in the servo amplifier

Checking method

Alarm (AL.15) occurs if power is
switched on after disconnection
of all cables but the control
circuit power supply cables.

AL.15

Memory error 2 EEP-ROM fault

2. The number of write times to EEP-

ROM exceeded 100,000.

Change the servo amplifier.

1. Encoder connector (CN2)

disconnected.

Connect correctly.

2. Encoder fault

Change the servo motor.

AL.16

Encoder error 1 Communication

error occurred
between encoder
and servo amplifier. 3. Encoder cable faulty

(Wire breakage or shorted)

Repair or change the cable.

CPU/parts fault

1. Faulty parts in the servo amplifier.

Checking method

Alarm (AL.17) occurs if power is
switched on after disconnection
of all cable but the control circuit
power supply cable.

Change the servo amplifier.

AL.17

Board error

The output
terminals U, V, W of
the servo amplifier
and the input
terminals U, V, W of
the servo motor are
not connected.

2. The wiring of U, V, W is

disconnected or not connected.

Correctly connect the output terminals U,
V, W of the servo amplifier and the input
terminals U, V, W of the servo motor.

AL.19

Memory error 3 ROM memory fault Faulty parts in the servo amplifier.

Checking method

Alarm (AL.19) occurs if power is
switched on after disconnection
of all cable but the control circuit
power supply cable.

Change the servo amplifier.

AL.1A

Motor
combination
error

Wrong combination
of servo amplifier
and servo motor.

Wrong combination of servo amplifier
and servo motor connected.

Use correct combination.

1. Encoder connector (CN2)

disconnected.

Connect correctly.

Communication
error occurred
between encoder
and servo amplifier.

2. Encoder cable faulty

(Wire breakage or shorted)

Repair or change the cable.

3. Encoder fault

Change the servo motor.

AL.20

Encoder error 2

Encoder detected

acceleration error.

4. Excessive acceleration is occurred

due to oscillation and others.

1. Decrease the speed control gain 2.

2. Decrease the auto tuning response

level.

1. Power input wires and servo motor

output wires are in contact at
main circuit terminal block (TE1).

Connect correctly.

2. Sheathes of servo motor power

cables deteriorated, resulting in
ground fault.

Change the cable.

AL.24

Main circuit
error

Ground fault
occurred at the
servo motor outputs
(U,V and W phases)
of the servo
amplifier.

3. Main circuit of servo amplifier

failed.

Checking method

AL.24 occurs if the servo is
switched on after disconnecting
the U, V, W power cables from
the servo amplifier.

Change the servo amplifier.