13. OPTIONS AND AUXILIARY EQUIPMENT

(2) Connection example

(Note 5)
Power supply

NFB

MC

Servo amplifier

L

11

L

21

L

1

L

2

L

3

SK

ON

MC

B C

RDY

SE

Alarm
output

RDY
output

A

B

C

Operation ready

MC

OFF

EMG

RA2

FR-RC

Ready

(Note 3) Power factor improving reactor

FR-BAL

R/L

1

S/L

2

T/L

3

B

C

EMG

SON

SG

COM

ALM

VDD

RA2

R

RX

R

SX

S

TX

T

Phase detection
terminals

(Note 1)

Power regeneration
converter FR-RC

N

P

5m(16.4ft) or less

N/

P/

(Note 2)

C

P

1

(Note 4)

Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the

FR-RC will not operate.

2. For the servo amplifiers of 5k and 7kW, always remove the wiring (across P-C) of the built-in regenerative resistor.
3. Refer to the power return converter FR-RC instruction manual (IB(NA)-66330) for the power factor improving reactor to be

used.

When using FR-RC with the servo amplifier of 11k to 22kW, do not use the power factor improving reactor (FR-BEL) together.
4. When using the servo amplifier of 11k to 22kW, make sure to connect P

1

and P. (Factory-wired.)

5. Refer to section 1.3 for the power supply specification.