5 - 13

5. PARAMETERS

Class No. Symbol

Name and function

Initial
value

Unit

Setting

range

Control

mode

Parameter write inhibit

Used to select the reference and write ranges of the parameters.
Operation can be performed for the parameters marked .

Set

value

Operation

Basic

parameters

No. 0

to No. 19

Expansion

parameters 1

No. 20

to No. 49

Expansion

parameters 2

No. 50

to No. 84

Reference

0000

(Initial

value)

Write

Reference

No. 19 only

000A

Write

No. 19 only

Reference

000B

Write

Reference

000C

Write

Reference

000E

Write

Reference

100B

Write

No. 19 only

Reference

100C

Write

No. 19 only

Reference

100E

Write

No. 19 only

B

asi

c pa

ra

m

et

ers

19

*BLK

0000

Refer to
Name
and
function
column.

P S T

20

*OP2

0000

Refer to
Name
and
function
column.

S

E

xpa

n

si

on

pa

ra

m

et

ers

1

Function selection 2

Used to select restart after instantaneous power failure,
servo lock at a stop in speed control mode, and slight vibration
suppression control.

Restart after instantaneous power failure
If the power supply voltage has returned to normal
after an undervoltage status caused by the reduction
of the input power supply voltage in the speed control
mode, the servo motor can be restarted by merely
turning on the start signal without resetting the alarm.
0: Invalid (Undervoltage alarm (AL.10) occurs.)
1: Valid

Selection of servo lock at stop
In the speed control mode, the servo motor shaft can
be locked to prevent the shaft from being moved by
the external force.
0: Valid (Servo-locked)
The operation to maintain the stop position is
performed.
1: Invalid (Not servo-locked)
The stop position is not maintained.
The control to make the speed 0r/min is performed.

Slight vibration suppression control
Made valid when auto tuning selection is set to
"0400" in parameter No. 2.
Used to suppress vibration at a stop.
0: Invalid
1: Valid

0

P S