beautypg.com

MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 10

background image

A - 9

(7) Auxiliary equipment and options

(a) The no-fuse breaker and magnetic contactor used should be the EN or IEC standard-compliant

products of the models described in section 13.2.2.

(b) The sizes of the cables described in section 13.2.1 meet the following requirements. To meet the

other requirements, follow Table 5 and Appendix C in EN60204-1.

Ambient temperature: 40 (104) [ ( )]
Sheath: PVC (polyvinyl chloride)
Installed on wall surface or open table tray

(c) Use the EMC filter for noise reduction.

(8) Performing EMC tests

When EMC tests are run on a machine/device into which the servo amplifier has been installed, it
must conform to the electromagnetic compatibility (immunity/emission) standards after it has
satisfied the operating environment/electrical equipment specifications.
For the other EMC directive guidelines on the servo amplifier, refer to the EMC Installation
Guidelines(IB(NA)67310).