Parameters – MITSUBISHI ELECTRIC MR-J2S- A User Manual
Page 148
5 - 25
5. PARAMETERS
Class No. Symbol
Name and function
Initial
value
Unit
Setting
range
Control
mode
Internal speed command 5
Used to set speed 5 of internal speed commands.
S
73
SC5
Internal speed limit 5
Used to set speed 5 of internal speed limits.
300
r/min 0 to in-
stanta-
neous
permi-
ssible
speed
T
Internal speed command 6
Used to set speed 6 of internal speed commands.
S
74
SC6
Internal speed limit 6
Used to set speed 6 of internal speed limits.
500
r/min 0 to in-
stanta-
neous
permi-
ssible
speed
T
Internal speed command 7
Used to set speed 7 of internal speed commands.
S
75
SC7
Internal speed limit 7
Used to set speed 7 of internal speed limits.
800
r/min 0 to in-
stanta-
neous
permi-
ssible
speed
T
76
TL2
Internal torque limit 2
Set this parameter to limit servo motor torque on the assumption
that the maximum torque is 100[%].
When 0 is set, torque is not produced. (Refer to section 3.4.1 (5))
100
%
0
to
100
P S T
77
00
78
10000
79
10
80
10
81
100
82
100
83
100
E
xpa
n
si
on
pa
ra
m
et
ers
2
84
For manufacturer setting
Do not change this value by any means.
0000