beautypg.com

Absolute position detection system – MITSUBISHI ELECTRIC MR-J2S- A User Manual

Page 387

background image

15 - 66

15. ABSOLUTE POSITION DETECTION SYSTEM

(2) ABS communication error

(a) The OFF period of the send data ready signal output from the servo amplifier is checked.

If the OFF period is 1s or longer, this is regarded as a transfer fault and the ABS communication
error is generated.
The ABS communication error occurs if the ABS time-out warning (AL.E5) is generated at the
servo amplifier due to an ABS request ON time time-out.

OFF

ON

OFF

ON

OFF

ON

1s

ABS transfer mode

ABS request

Send data ready

ABS communication
error

The signal does not come ON

NO

YES

(b) The time required for the ABS transfer mode signal to go OFF after it has been turned ON (ABS

transfer time) is checked.
If the ABS transfer time is longer than 5s, this is communication error occurs if the ABS time-out
warning (AL.E5) is generated at the servo amplifier due to an ABS transfer mode completion time
time-out.

OFF

ON

OFF

ON

OFF

ON

1

2

3

4

18

19

1

2

3

4

18

19

5s

ABS transfer mode

ABS request

Send data ready

ABS communication
error

The signal does not go OFF

NO

YES