3. SIGNALS AND WIRING

(3) Pulse train input interface DI-2

Provide a pulse train signal in the open collector or differential line driver system.

(a) Open collector system

1) Interface

For use of internal power supply

For use of external power supply

VDD

OPC

PP, NP

SG

SD

Max. input pulse
frequency 200kpps

About 1.2k

24VDC

2m (78.74in) or less

(Note)

Servo amplifier

24VDC

Do not connect
VDD-OPC.

VDD

OPC

PP, NP

SG

SD

Max. input pulse
frequency 200kpps

About 1.2k

24VDC

2m (78.74in) or less

(Note)

Servo amplifier

Note. Pulse train input interface is comprised of a photo coupler.

Therefore, it may be any malfunctions since the current is reduced when connect a resistance to a pulse train signal line.

2) Conditions of the input pulse

0.9
0.1

tc

tHL

tc

tLH

tF

tLH tHL 0.2 s
tc 2 s
tF 3 s

PP

NP