Characteristics – MITSUBISHI ELECTRIC MR-J2S- A User Manual
Page 223
12 - 2
12. CHARACTERISTICS
12.2 Power supply equipment capacity and generated loss
(1) Amount of heat generated by the servo amplifier
Table 12.1 indicates servo amplifiers' power supply capacities and losses generated under rated load.
For thermal design of an enclosure, use the values in Table 12.1 in consideration for the worst
operating conditions. The actual amount of generated heat will be intermediate between values at
rated torque and servo off according to the duty used during operation. When the servo motor is run at
less than the maximum speed, the power supply capacity will be smaller than the value in the table,
but the servo amplifier's generated heat will not change.
Table 12.1 Power supply capacity and generated heat per servo amplifier at rated output
(Note 2)
Servo amplifier-generated heat[W]
Area required for heat dissipation
Servo amplifier
Servo motor
(Note 1)
Power supply
capacity[kVA]
At rated torque
With servo off
[m
2
]
[ft
2
]
HC-KFS053 13
0.3
25
15
0.5
5.4
HC-MFS053 13
0.3
25
15
0.5
5.4
MR-J2S-10A(1)
HC-UFS13
0.3
25
15
0.5
5.4
HC-KFS23
0.5
25
15
0.5
5.4
HC-MFS23
0.5
25
15
0.5
5.4
MR-J2S-20A(1)
HC-UFS23
0.5
25
15
0.5
5.4
HC-KFS43
0.9
35
15
0.7
7.5
HC-MFS43
0.9
35
15
0.7
7.5
MR-J2S-40A(1)
HC-UFS43
0.9
35
15
0.7
7.5
HC-SFS52
1.0
40
15
0.8
8.6
HC-SFS53
1.0
40
15
0.8
8.6
MR-J2S-60A
HC-LFS52
1.0
40
15
0.8
8.6
HC-KFS73
1.3
50
15
1.0
10.8
HC-MFS73
1.3
50
15
1.0
10.8
MR-J2S-70A
HC-UFS72 73
1.3
50
15
1.0
10.8
HC-SFS81
1.5
50
15
1.0
10.8
HC-SFS102 103
1.7
50
15
1.0
10.8
MR-J2S-100A
HC-LFS102
1.7
50
15
1.0
10.8
HC-SFS121
2.1
90
20
1.8
19.4
HC-SFS201
3.5
90
20
1.8
19.4
HC-SFS152 153
2.5
90
20
1.8
19.4
HC-SFS202 203
3.5
90
20
1.8
19.4
HC-RFS103
1.8
50
15
1.0
10.8
HC-RFS153
2.5
90
20
1.8
19.4
HC-UFS152
2.5
90
20
1.8
19.4
MR-J2S-200A
HC-LFS152
2.5
90
20
1.8
19.4
HC-SFS301
4.8
120
20
2.7
29.1
HC-SFS352 353
5.5
130
20
2.7
29.1
HC-RFS203
3.5
90
20
1.8
19.4
HC-UFS202
3.5
90
20
1.8
19.4
MR-J2S-350A
HC-LFS202
3.5
90
20
1.8
19.4