Motorola ATCA-717 User Manual
Page 94
BIOS
BIOS Messages
94
PENT/ATCA−717
Message
Corrective Action
Explanation
a
Keyblade error
Keyblade not working
Check for correct keyblade
connection.
Keyblade error nnn
BIOS discovered a stuck
key and displays scan code
nn for stuck key
Replace keyblade, check for
stuck keys
Operating system not found
Operating system cannot
be located on either drive
A: or drive C:.
Enter setup and check if
fixed disk and drive A: are
properly identified.
Parity Check 1 nnnn
Parity error found in
system bus. BIOS attempts
to locate address nnnn and
display it on screen. If it
cannot locate the address, it
displays ????.
Check for correct memory
module types.
Parity Check 2 nnnn
Parity error found in
system bus. BIOS attempts
to locate address nnnn and
display it on the screen. If it
cannot locate the address, it
displays ????.
Check for correct memory
module types.
Press
to setup
Displayed after any
recoverable error message
Press
process or
setup and change any
settings.
Previous boot incomplete −
Default configuration used
Previous POST did not
complete successfully.
POST loads default values
and offers to run setup. If
failure was caused by
incorrect values and they
are not corrected, the next
boot will likely fail.
Run setup to restore
original configuration. This
error is cleared the next
time the system is booted.
Real time clock error
Real−time clock fails BIOS
test
May require blade repair
Resource allocation
conflict on motherblade −
Run Configuration Utility
Possible interrupt or
interface resource conflict.
Run ISA or EISA
Configuration Utility to
resolve resource conflict.
Shadow RAM Failed at
offset: nnnn
Shadow RAM failed at
offset nnnn of the 64k block
at which error was
detected.
Contact your local sales
representative or FAE for
further support.
nnnn Shadow RAM Passed
nnnn is amount of shadow
RAM in KBytes
successfully tested
None