5 specifications, Requirement, Command port – Multi-Tech Systems MTASR1-100 User Manual
Page 21: Ethernet port, Specifications, Electrical/physical, Wan link

Chapter 1 - Introduction and Description
21
1.5
Specifications
The RouteFinder
100
conforms to the following specifications.
•
Routing Protocols - IP and IPX and bridging all others
•
EtherNet LAN Interface - 10Base-T (twisted pair) or 10Base2 (ThinNet) BNC
•
WAN Interface - 3 async or sync Links (RS232C/V.35)
•
Command Port - 19.2K bps Asynchronous
•
One 4megabyte DRAM (1 meg by 36 byte at 70
Caution: SIMM speed and size can not be mixed.
•
1MB of Flash memory
EtherNet Port
•
One Ethernet Interface - 10Base-T (twisted pair) RJ45 (ThinNet) BNC connector
Command Port
•
Single 19.2K bps asynchronous Command Port using a
short RJ45 to DB25 cable with
a female connector
WAN Link
•
115.2K bps asynchronous WAN link or T1 (1.544Mbps) sync link using DB25 male connector. Optional
ITU-T V.35 interface using a V.35 adapter cable.
Electrical/Physical
•
Voltage - 115 VAC (Standard), 240 Volts AC (Optional)
•
Frequency - 47 to 63 Hz
•
Power Consumption - 10 Watts
•
Dimensions -1.625" high x 6" wide x 9" deep
.63cm high x 2.34cm wide x 3.51cm deep
•
Weight - 2 pounds (.92 kg)
Requirement
•
PC with Windows 3.1x, one serial comm port to connect to the Command Port of the RouteFinder
100