2 mute – Kramer 4 x 4 Seamless AV Matrix Switcher/Multi-Scaler User Manual
Page 99

92
VSM-4x4A
–
VSM-4x4A RS-232/Ethernet Communication Protocol
10.3.5.2
MUTE
Functions
Permission
Transparency
Set:
MUTE
End User
Public
Get:
MUTE?
End User
Audio
Description
Syntax
Set:
Mute the selected output
#MUTESPchannel,mute_modeCR
Get:
Mute the selected output
#MUTE?SPchannelCR
Response
Set / Get: ~
nn@MUTESPchannel,mute_modeCR LF
Parameters
channel
–
*
(All)
mute_mode
– mute the output:
0
(Off, unmute),
1
(On, mute)
Response triggers
Response is sent to the com port from which the
Set
(before execution)
/ Get
command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control
device (button press, device menu and similar) or genlock status was changed
Notes
Mutes the audio output
K-Config Example
Mute the outputs:
“#MUTE
*
,1”,0x0D