4 scaler-as, 5 show-osd – Kramer 4 x 4 Seamless AV Matrix Switcher/Multi-Scaler User Manual
Page 105

98
VSM-4x4A
–
VSM-4x4A RS-232/Ethernet Communication Protocol
10.3.7.4
SCALER-AS
Functions
Permission
Transparency
Set:
SCLR-AS
End User
Public
Get:
SCLR-AS?
End User
Audio
Description
Syntax
Set:
Set the auto sync off timer
#
SCLR-AS
SPP1,P2CR
Get:
Get the auto sync off timer definition
#
SCLR-AS?
SPP1CR
Response
Set / Get: ~
nn@
SCLR-AS
SPP1,P2CR LF
Parameters
P1
–
*
(All)
P2
– For setting the auto sync timer:
0
(Disable),
1
(Fast, 10sec),
2
(Slow, 2min)
Response triggers
The auto-sync feature determines whether the outputs are turned off when no video is detected on the
selected input
Notes
All 4 scalers have the same auto sync off timer
K-Config Example
Set the auto sync off timer to slow:
“#SCLR
-AS *
,2”,0x0D
10.3.7.5
SHOW-OSD
Functions
Permission
Transparency
Set:
SHOW-OSD
End User
Public
Get:
SHOW-OSD?
End User
Public
Description
Syntax
Set:
Set the OSD of the selected channel
#
SHOW-OSD
SPP1,P2CR
Get:
#
SHOW-OSD?
SPp1CR
Response
Set / Get: ~
nn@
SHOW-OSD
SPP1,P2CR LF
Parameters
P1
–
*
(All)
P2
–
1
(Off),
1
(On)
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if
SHOW-OSD
was set any other external control device
(button press, device menu and similar) or genlock status was changed
Notes
All 4 scalers have the same aspect ratio