2 build-date, 3 factory – Kramer 4 x 4 Seamless AV Matrix Switcher/Multi-Scaler User Manual
Page 85

78
VSM-4x4A
–
VSM-4x4A RS-232/Ethernet Communication Protocol
10.3.1.2
BUILD-DATE
Functions
Permission
Transparency
Set:
BUILD-DATE
End User
-
Get:
-
-
-
Description
Syntax
Set:
Get:
get device build date
#
BUILD-DATE?
CR
Response
~nn@
BUILD-DATE
SPdateSPtimeCR LF
Parameters
date
–
Format:
YYYY/MM/DD
where
YYYY
= Year,
MM
= Month,
DD
= Day
time
–
Format:
hh:mm:ss
where
hh
= hours,
mm
= minutes,
ss
= seconds
K-Config Example
Read the device build date:
“#BUILD
-
DATE?”,0x0D
10.3.1.3
FACTORY
Functions
Permission
Transparency
Set:
FACTORY
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory defaults configuration
#
FACTORY
CR
Get:
-
-
Response
~
nn@FACTORYSPOKCR LF
Notes
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
K-Config Example
Reset the device to its factory default configuration:
“#FACTORY”,0x0D