@AIT
Automatic input measurement including aspect
Command
format
@AIT, ch (, mode)
Return value
format
@AIT, ch (, mode)
Parameter
ch
: Input channel
6 = IN6 to 9 = IN9
mode
: Measuring mode
-1 = NEXT ASPECT, 0 = 4:3, 1 = 5:4, 2 = 5:3, 3 = 16:9, 4 = 16:10
If you select “NEXT ASPECT”, the next aspect ratio will be selected at each
execution in order. If you do not set any mode parameter, “NEXT ASPECT” mode
will be applied.
Example Send
Receive
@AIT,6
@AIT,6
Measure input timing settings of IN6 automatically with
“NEXT ASPECT” mode.
Terminated normally
Send
Receive
@AIT,6,3
@AIT,6,3
Measure input timing settings of IN6 automatically with
the aspect ratio of 16:9.
Terminated normally.
Send
Receive
@AIT,6
@ERR,7
If automatic measurement fails, an error is replied.
Related info.
8.6.6 Analog input automatic measurement
Note
This command is valid only if analog RGB or YPbPr signals are input and the
desired input channel is selected for one of the outputs.
@SIS
Set automatic measurement of start position
Command
format
@SIS, ch, mode
Return value
format
@SIS, ch, mode
Parameter
ch
: Input channel
0 = All analog inputs 6 = IN6 to 9 = IN9
mode
: Auto measurement
0 = All inputs from this input channel are not measured automatically.
1 = Current input signals are not measured automatically.
2 = Current input signals are measured automatically. [Default]
Example Send
Receive
@SIS,6,1
@SIS,6,1
Not measure signals currently input from IN6
automatically.
Terminated normally.
Related info.
8.6.7 Automatic measurement of start position