Filter maintenance – Hawk Industries Hawkjaw Sr. Manual 100K-2GSR Serial Numbers 101 to 120 User Manual
Page 34
![background image](/manuals/460488/34/background.png)
34
Maintenance & Repair
Filter Maintenance
Change Every 2 Months
Initial Steps
1. Depress the Red button (RB)
located under the See-through
rubber weather cap (SC).
2. Operate the HawkJaw.
3. If the Red button pops up,
proceed with Step 4.
4. Make sure the HawkJaw is off
the drill pipe connection and in
the rest position on the derrick.
5. Shut down the Hydraulic
power unit.
6. Press the Grip button
repeatedly to bleed hydraulic
pressure.
7. Disconnect the Air power
supply.
8. Push in the "E" stop.
9. Assume that there is still
pressure in the Pressure Line.
Proceed with caution.
Hydraulic Filter
1. Remove the Filter Cannister
(C).
2. Remove the Filter Element (E).
3. Insert the new Filter Element.
4. Replace the Filter Cannister
(C).
Part Numbers
Part Name
Part #
Filter
061-H25
Filter Element (E)
061-H25A
Filter Cannister/Body (C) 061-H25B
Weather Cap (RB)
061-H25RC
Filter Seal Kit (S)
061-H25SK
Hydraulic Filter
WARNING
Running the HawkJaw
without a Hawk approved
pressure-side filter element
(Part # 061-H25A) voids
the warranty and severely
shortens component life.
NOTE
If the Cannister
(C) leaks, change
the "O" ring and
back-up (S).
RB
C
S
SC
E