Start-up Procedure
1. Connect the air power source
with the Air (A) line.
2. Make sure the hydraulic
reservoir is full.
3. Make sure the hydraulic
Pressure (P) and Tank (T) lines
are connected. The Pressure line
(P) Quick Disconnect is male.
4. Make sure the "E" stop (E) is
pulled out.
5. Check for hydraulic leaks. If
leaks occur, see Trouble
Shooting.
6. With the exception of the hooks
retracting, no motion should
occur. If any other parts on the
HawkJaw move, see Trouble
Shooting.
E
Operation
NOTE
Tightly connect the quick
disconnects. A loose connection
causes a pressure drop in the
hydraulic fluid which heats up the
fluid and reduces component life.
NOTE
Use only Hawk approved quick
disconnects.