Winch Hook - Up

14

Installation

1. Connect the air power source

with the Air (A) line.

2. Make sure the hydraulic

reservoir is full.

3. Connect the hydraulic Pressure

(P) and Tank (T) lines. The
Pressure line (P) Quick
Disconnect is male.

4. Make sure the "E" stop (E) is

pulled out.

5. Check for hydraulic leaks. If

leaks occur, see Trouble
Shooting.

6. With the exception of the hooks

retracting, no motion should
occur. If any other parts on the
HawkJaw move, see Trouble
Shooting.

Part Numbers

Part Name

Part #

Male Quick Disconnect (P)

061-H52

Female Quick Disconnect (T) 061-H53
Male Air Quick Disc. (A)

061-A12M

Female Air Quick Disc.

061-A12F

Continued on next page.

NOTE

Use only Hawk approved quick
disconnects
.

P

T

A

E

NOTE

Tightly connect the quick disconnects.
A loose connection causes a pressure drop
in the hydraulic fluid which heats up the fluid