Wrench Maintenance

Tools Required

1. Make sure the HawkJaw is off

the drill pipe connection and in
the rest position on the derrick.

2. Shut down the Hydraulic

power unit.

3. Press the Grip button

repeatedly to bleed hydraulic
pressure.

4. Disconnect the Air power

supply.

5. Push in the "E" stop.
6. Assume that there is still a load

on every actuator. Proceed with
caution.

Initial Steps

Grease gun

Mounting Arm Pivot Points

1. Pump grease fittings MP1-MP3

on each Mounting Arm (M1,
M2).

MP3

Part Numbers

Part Name

Part #

Straight Grease Fitting

061-1103K1

45° Grease Fitting

061-1103K2

90° Grease Fitting

061-1103K3

NOTE

Consistent lubrication of the mounting

arm pivot points increases perfor-

mance and component life.

MP2

MP1

M1

M2

E

Grease Once per Week, Minimum

Maintenance & Repair

33

Maintenance

& Repair