Power Supply and Wiring

Section 6

(continued)

Single Phase Connection

For small drives with diode rectifier front end it is possible to run a three phase output with a single phase

input. Only part of the three phase input bridge is used. Ripple current becomes 120 Hz rather than 360. This

places a greater demand on the DC filter components (capacitor bank and DC choke). The result is that the

drive must be derated to 50% current.

The chart below shows the full load output current ratings of the controller when single phase or 3 phase

power is used. If single phase input power is used the Motor Overload switches must be set to 50% or lower.

Nominal

Controller Full Load

HP Rating

Output Current Rating

Supply

Frame

Model

3 Phase

1 Phase

3 Phase

1 Phase

Voltage

Size

Number

Input

Input

Input

Input

1

SPD20050

5.0

2.0

17.8

8.1

SPD20050F

SPD20075

7.5

3.0

26.4

10.9

2

SPD20075F

SPD20100

10.0

5.0

37.0

17.8

SPD20100F

208/230

SPD20150

15.0

7.5

47.4

26.4

3

SPD20150F

SPD20200

20.0

10.0

60.6

33.0

SPD20200F

SPD20250

25.0

12.0

76.0

40.2

4

SPD20250F

SPD20300

30.0

15.0

94.0

47.4

SPD20300F

SPD40050

5.0 8.9

1

SPD40050F

SPD40075

7.5 13.2

SPD40075F

SPD40100

10.0 18.5

SPD40100F

460

2

SPD40150

15.0 23.7

SPD40150F

SPD40200

20.0 30.3

SPD40200F

SPD40250

25.0 37.5

3

SPD40250F

SPD40300

30.0 47.0