HP 2100 ER User Manual
Page 44
3-8
Chapter 3
Operating the Fibre Bridge
Changing the Default Settings
Table 3-1
Fibre Bridge Default Configuration Settings
Serial Port
• Baud rates: 9600, 19200, 38400, 57600, 115200
(baud rate will auto-configure).
• No handshake.
• No parity.
• 8 data bits.
• 1 stop bit.
Fibre
Channel
• Hard address mode uses address 0x82.
• User may change both address mode and hard
address.
SCSI
Initiator address 7.
Bus automatically negotiates for wide ultra SCSI
performance, per ANSI SCSI specifications.
Only the initiator addresses may be changed.
Each bus can be set to its own initiator address
independently of the other bus.
Trace Debug
Level
Level 0, 1, 2, and 3.
This manual is related to the following products:
- Surestore 2.20 Tape Library Surestore DLT 4000 15 Tape Library Surestore 1.8 Tape Library Surestore DLT 718 Tape Autoloader Surestore DLT 818 Tape Autoloader Surestore DLT 7000 28.48 Tape Library Surestore 2.28 Tape Library Surestore E 4.40 Tape Library Surestore E 6.60 Tape Library Surestore DLT 418 Tape Autoloader Surestore DLT 7000 15 Tape Library Surestore E 2.20 Tape Library Surestore 4.40 Tape Library Surestore 6.60 Tape Library Surestore 10.588 Tape Library Surestore 2.15 Tape Library Surestore 3.30 Tape Library Surestore 6.100 Tape Library Surestore SCSI-FC Bridges Surestore DLT 4000 28.48 Tape Library