Enww troubleshooting menu 57 – HP CM6049F MFP User Manual
Page 73
Menu item
Sub-menu item
Sub-menu item
Values
Description
Repeat
Once
(Default)
Continuous
Determines the number of times the test runs.
Print/Stop Test
Continuous value
from 0 to 60,000
milliseconds.
Default: 0
Isolate faults by stopping the device during
the print cycle and observing where in the
process the image degrades. To run the test,
specify a stop time. The next job that is sent
to the device stops at the specified time in the
process.
Color Band Test
Test Page
Prints a page that helps identify arcing in the
high-voltage power supplies.
Copies
Continuous value
from 1 to 30.
Default: 1
Specify the number of copies to print for the
Color Band test
Scanner Tests
Lower Lamp
Sensors
ADF Input Motor
ADF Input Reverse
Flatbed Motor
ADF Read Motor
ADF Read Motor
Reverse
ADF Duplex
Solenoid
ADF LED Indicator
A service technician can use this menu item
to diagnose potential problems with the
device scanner.
Control Panel
LEDs
Verify that the components of the control
panel are functioning correctly.
Display
Buttons
Touchscreen
Finisher Tests
Manual Sensor Test
Component Test
Table 2-17
Troubleshooting menu (continued)
ENWW
Troubleshooting menu
57