beautypg.com

Error/warning indications, Error indications, Warning indications – Sony LA-EA5 A-Mount to E-Mount Adapter User Manual

Page 127: Error indications warning indications

background image

Error/Warning Indications

127

Ap
pend

ic

es

The camcorder informs you of situations where warning, caution, or an operation check is required,
through messages on the viewfinder screen, the REC lamp, and a buzzer.
The buzzer is output to the built-in speaker or to the headphones connected via the headphone connector.
When the camcorder is turned on, the message for prompting the APR function appears on the viewfinder
screen if the auto adjustment for the image sensor (APR) has not performed for a period of time. In this
case, perform “APR”

(page 104)

by following the displayed message.

The camcorder stops operation after the following indications.

When one of the following indications is generated, follow the message to resolve the problem.

Error/Warning Indications

Error Indications

Error indication on
LCD/viewfinder

Buzzer

REC
lamp

Cause and measures

E + Error code

Continuous

Rapidly
flashing

The camcorder may be defective. Recording stops even if

z

REC is displayed on the viewfinder screen.

Turn off the power and check the connected equipment, cables,
and media. If they are not defective, turn on the power again. If
the error persists, consult Sony service personnel.
(If power cannot be turned off by setting the power switch to
OFF, remove both the battery pack or the DC IN source.)

Warning Indications

Warning indication
on LCD/viewfinder

Buzzer

REC
lamp

Cause and measures

Media Near Full

Intermittent

Flashing

Free space on the SxS memory card has become insufficient.
Replace it with another at the earliest opportunity.

Media Full

Continuous

Rapidly
flashing

No space is left on the SxS memory card. Recording, clip
copying and clip division cannot be performed.
Replace it with another.

Battery Near End

Intermittent

Flashing

The battery power will be discharged soon.
Charge the battery pack at the earliest opportunity.

Battery End

Continuous

Rapidly
flashing

The battery pack is discharged. Recording cannot be
performed.
Stop operation and change the battery pack.

Temperature High

Intermittent

Flashing

The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.

Voltage Low

Intermittent

Flashing

The DC IN voltage has become low (stage 1).
Check the power supply.

Insufficient Voltage

Continuous

Rapidly
flashing

The DC IN voltage is too low (stage 2). Recording cannot be
performed.
Connect another power source.

EXT. I/F Signal Error

An error was detected with the signal in the mounting terminal
for an expansion unit.
Check the connection to the AXS-R5/R7, etc.