RLX2 Industrial Hotspot Series

Page 120 of 212

ProSoft Technology, Inc.

June 15, 2015

Field

Description

EOL Time Gap

Available when the selected Delineation Method is Time Gap; This value
configures the length of time in milliseconds that must elapse after a
character is received (from the local attached device) before that character
marks the end of a packet.
NOTE: the smallest value this field can be set to will be limited by the device
and is platform dependent.

Packet Rate (milliseconds)

Sets the minimum time gap that will be interpreted as an inter-packet space.
When detected the characters received up to that point will constitute a
single packet and will be sent to the remote node. Units: microseconds.
Values: 1,000 to 500,000.

Baud Rate

Baud rate on the radio must match the baud rate on the connected serial
device.

Data Bits

Number of data bits (5, 6, 7 or 8). The data bits on the radio must match the
data bits on the connected serial device.

Parity

Parity (None, Even, Odd, 1 or 0). The parity on the radio must match the
parity on the connected serial device.

Flow Control

Flow control (handshaking) mode (None or Hardware). The handshaking
mode on the radio must match the handshaking mode on the connected
serial device.

Stop Bits

Stop bits (1 or 2). The stop bits on the radio must match the stop bits on the
connected serial device.

Save

Saves the changes and updates the radio configuration.

Cancel

Discards the changes without updating the radio configuration.