6.11.3 Archive Types

The module supports two types of archives: hourly archives and daily archives:

Archive Type

Period Period

End

Number of 30-Word
Archives Stored Locally

Hourly

60 minutes (1 hour)

Set by End-of-Hour Minute parameter

48

Daily

1440 minutes (1 day) Set by End-of-Day Minute parameter

35

The Period End parameters must be set using the AFC Manager (Site
Configuration). The default value is zero for both archive types which means that:

Daily Archives are generated every day at midnight (00:00)

Hourly Archives are generated every hour on the hour (1:00, 2:00, 3:00, 4:00)

For example, if the parameters are configured as follows:
End-of-day minute = 480

The daily archives would be created every day at 08:00.
End-of-hour minute = 30

The hourly archives would be created every hour at 1:30, 2:30, 3:30, 4:30, and
so on.