3 event id tag – ProSoft Technology PTQ-AFC User Manual

Page 116

background image

Quick Start

PTQ-AFC ♦ Modicon Quantum Platform

User Manual

Liquid and Gas Flow Computer for Hydrocarbon Products

Page 116 of 259

ProSoft Technology, Inc.

June 23, 2011

6.12.3 Event Id Tag

This 32-bit field has the following structure:

Bits

N

Meaning

31

1

0 Special, 1 Datum Point (e.g. sealable parameter)
If this bit is clear, then bits 19-00 contain a value from the Special event
tag list below; if the bit is set, then bits 19-00 have the interpretation
given here.

30

1

PLC offline; timestamp may not be accurate
This bit may also be set for a Special event.

29

1 [reserved]

28 to 24

5

Meter number, or 0 for Site
This field may also be set for a Special event.

23 to 20

4

[Meter] Stream number or 0; [Site] 0
This field may also be set for a Special event.

19 to 16

4

Datum type:

Value

Mnemonic

Format

0

Ubyt

Unsigned byte

1

Usht

Unsigned short integer

2

[reserved]

3

Ulng

Unsigned long integer

4

Sbyt

Signed byte

5

Ssht

Signed short integer

6

[reserved]

7

Slng

Signed long integer

8

Bbyt

Bitmap (up to 8 bits)

9

Bsht

Bitmap (up to 16 bits)

10

Bm24

Bitmap (up to 24 bits)

11

Blng

Bitmap (up to 32 bits)

12

Bool

Boolean (value 0 or 1)

13

DiBy

Dibyte (both high and low)

14

B448

Bitfield nybble/nybble/byte

15

Flot

Floating point

15 to 12

4

[reserved]

11 to 08

4

Group code
This value is one of the "measurement configuration changed" bit
numbers.

07 to 04

4

Subgroup code
This value is the ordinal number (starting at 0) of the subgroup of
parameters in the specified group.

03 to 00

4

Subgroup item code
Since a parameter subgroup may contain more than one item, this value
identifies the particular item; items are numbered from 0.