ProSoft Technology PTQ-AFC User Manual
Page 153
PTQ-AFC ♦ Modicon Quantum Platform
Meter Proving
Liquid and Gas Flow Computer for Hydrocarbon Products
User Manual
ProSoft Technology, Inc.
Page 153 of 259
June 23, 2011
Variation Limit Alarms
These alarms are due to variation outside the configured limits:
Bit/Byte
Description Modbus
Dictionary
Address
01
Prover inlet temperature
65050
02
Prover outlet temperature
65052
03
Prover inlet-outlet temperature
65054
04
Prover temperature
65056
05
Prover-meter temperature
65058
06
Switch bar temperature
65060
07
Meter pressure
65062
08
Prover inlet pressure
65064
09
Prover outlet pressure
65066
10
Prover inlet-outlet pressure
65068
11
Prover pressure
65070
12
Prover-meter pressure
65072
13
Meter density
65074
14
Prover density
65076
15
Prover-meter density
65078
16
Water content
65080
17
Meter flow rate
65082
18
Prover flow rate
65084
19
Pulses over runs
65086
20
Pulses over passes
65088
21
Not enough pulses in run
N/A
22-31