ProSoft Technology PTQ-AFC User Manual
Page 190
Backplane Communication
PTQ-AFC ♦ Modicon Quantum Platform
User Manual
Liquid and Gas Flow Computer for Hydrocarbon Products
Page 190 of 259
ProSoft Technology, Inc.
June 23, 2011
STRUCT
SlaveAddress: INT;
Direction_RegisterBank: INT;
Size_Swap: INT;
RegisterAddress: INT;
RegisterCount: INT;
ErrorCount: INT;
Data: ARRAY[1..119] OF INT;
END_STRUCT;
END_TYPE
TYPE
MODBUS_PASS_THRU:
STRUCT
TransactionPending: INT;
Word_Bit_Select: INT;
RegisterAddress: INT;
RegisterCount: INT;
Data: ARRAY[1..122] OF INT;
END_STRUCT;
END_TYPE
Variable Definitions
There are four variable definition files available:
Description
File Name
PTQVAR_DIFF_GAS.TXT
Variables definition for Differential/Gas applications
PTQVAR_LINEAR_GAS.TXT
Variables definition for Linear/Gas applications
PTQVAR_DIFF_LIQ.TXT
Variables definition for Differential/Liquid applications
PTQVAR_LINEAR_LIQ.TXT
Variables definition for Linear/Liquid applications
These files are presented in "csv" format and refer to data types available in the
PTQAFCDATATYPES.DTY file.
Using Concept, open the File menu and then choose Import / Variables: Text
delimited
to import the variable definition file to your project.