1 process input from plc to afc – ProSoft Technology PTQ-AFC User Manual
Page 179
PTQ-AFC ♦ Modicon Quantum Platform
Backplane Communication
Liquid and Gas Flow Computer for Hydrocarbon Products
User Manual
ProSoft Technology, Inc.
Page 179 of 259
June 23, 2011
9.2.1 Process Input from PLC to AFC
This block is continuously copied from the Quantum to the PTQ-AFC. It allows
the processor to:
Disable
the
meter
Transfer process variables to PTQ-AFC
Transfer molar concentrations to the module
For proper operation of the PTQ-AFC, for an enabled meter this block is required
and must be defined.
The process variable words depend on the configured meter type/product group.
Offset
Description Type
Comments
0
Meter Disable
Signal
1
Process Variable Word 0
Output
2
Process Variable Word 1
Output
3
Process Variable Word 2
Output
4
Process Variable Word 3
Output
5
Process Variable Word 4
Output
6
Process Variable Word 5
Output
7
Process Variable Word 6
Output
8
Process Variable Word 7
Output
9
Process Variable Word 8
Output
10
Process Variable Word 9
Output
11
Process Variable Word 10
Output
12
Molar Analysis - C1
Output
Scaled Integer Format (10000 = 100%)
13
Molar Analysis - N2
Output
Scaled Integer Format (10000 = 100%)
14
Molar Analysis - CO2
Output
Scaled Integer Format (10000 = 100%)
15
Molar Analysis - C2
Output
Scaled Integer Format (10000 = 100%)
16
Molar Analysis - C3
Output
Scaled Integer Format (10000 = 100%)
17
Molar Analysis - H2O
Output
Scaled Integer Format (10000 = 100%)
18
Molar Analysis - H2S
Output
Scaled Integer Format (10000 = 100%)
19
Molar Analysis - H2
Output
Scaled Integer Format (10000 = 100%)
20
Molar Analysis - CO
Output
Scaled Integer Format (10000 = 100%)
21
Molar Analysis - O2
Output
Scaled Integer Format (10000 = 100%)
22
Molar Analysis - iC4
Output
Scaled Integer Format (10000 = 100%)
23
Molar Analysis - C4
Output
Scaled Integer Format (10000 = 100%)
24
Molar Analysis - iC5
Output
Scaled Integer Format (10000 = 100%)
25
Molar Analysis - C5
Output
Scaled Integer Format (10000 = 100%)
26
Molar Analysis - C6
Output
Scaled Integer Format (10000 = 100%)
27
Molar Analysis - C7
Output
Scaled Integer Format (10000 = 100%)
28
Molar Analysis - C8
Output
Scaled Integer Format (10000 = 100%)
29
Molar Analysis - C9
Output
Scaled Integer Format (10000 = 100%)
30
Molar Analysis - C10
Output
Scaled Integer Format (10000 = 100%)
31
Molar Analysis - He
Output
Scaled Integer Format (10000 = 100%)
32
Molar Analysis - Ar
Output
Scaled Integer Format (10000 = 100%)
33
Molar Analysis - neo C5
Output
Scaled Integer Format (10000 = 100%)
34
Molar Analysis - Ux
Output
Scaled Integer Format (10000 = 100%)
35
Molar Analysis - Uy
Output
Scaled Integer Format (10000 = 100%)