PTQ-AFC ♦ Modicon Quantum Platform

Quick Start

Liquid and Gas Flow Computer for Hydrocarbon Products

User Manual

ProSoft Technology, Inc.

Page 111 of 259

June 23, 2011

bit 10 Analysis total not normalized -

bit 11 AGA8 calculation error -

bit 12 API calculation error, density correctio -

bit 13 API calculation error, Ctl -

bit 14 API calculation error, vapor pressure -

bit 15 API calculation error, Cpl -

Status

Bits

bit 11 Meter was enabled -

bit 12 Backplane communication fault -

bit 13 Measurement configuration changed -

bit 14 Power up -

bit 15 Cold start -

AFC-56(16) Daily Archive Date: 16-09-2002 16:26:44

Site Name: MVI Flow Station

Project: AFC

___________________________________________________________________________

Meter 1:

Tag M01

Archive 2

Closing timestamp of archive 2002-04-26.23:59:42

Opening timestamp of archive 2002-04-26.06:16:34

Status bitmap (details below) 60h

Alarms bitmap (details below) 0000h

Flowing period 1019877652

Event counter 53

Net accumulator (x f3) 174811

Net accumulator residue (x f3) 0,9399567

Net flow rate (x f3/h) 40247,88

Temperature (°F) 15,00736

Pressure (psig) 1000,416

Differential pressure (hw) 22,00479

Relative density (60°F/60°F) 0,7404

Reference compressibility 0,9989

Flowing compressibility 0,9053

Fpv 1,0506

Velocity of approach factor Ev 1,0331

Expansion factor Y 1,0001

Discharge coefficient 0,6045

Alarm

Bits

bit 0 Temperature input out of range -

bit 1 Pressure input out of range -

bit 2 Diff. pressure input out of range -

bit 3 Flowing density input out of range -

bit 4 Water content input out of range -

bit 5 Diff. pressure low -

bit 8 Orifice characterization error -

bit 9 Analysis total zero -

bit 10 Analysis total not normalized -

bit 11 AGA8 calculation error -