ProSoft Technology PTQ-AFC User Manual
Page 162
Meter Proving
PTQ-AFC ♦ Modicon Quantum Platform
User Manual
Liquid and Gas Flow Computer for Hydrocarbon Products
Page 162 of 259
ProSoft Technology, Inc.
June 23, 2011
8.3
Meter Proving Reports
Clicking on the R
EPORT
button generates a report with such information as:
Manufacturer
Model
Number
Serial
Number
Material
Type
Prover
Tag
Results of the prove will appear in this report, along with the static data
entered in the text window during setup. For more information, see Initial
Requirements (page 150).
The Meter Proving window above shows the system during a prove using a
Master Meter. Notice the differences in the example of the information that is
available before and after connecting to the module.